Floor heating user attention

issuing time :2018-11-14

1, low temperature hot water floor radiant heating system of the water temperature should not be more than 60 ℃, heating system working pressure shall not exceed 0.8 MPa. But here refers to is not to say that the water temperature of the heating boiler and working pressure, heating water temperature of the heating boiler must be up to 80 ℃.


2, at the start of water floor heating system or in use process, the pipe may be stored up in the air, heating effect, then can open ℃, Siamese bleed valve, the gas discharge, the method is the same as the traditional heating.


3, the system flow of each branch can be regulated through regulating ball valve in the bar, and thus achieve the purpose of temperature control parts, but should be carefully so as not to affect other branch during adjustment.


4, laying on the ground of floor heating pipe only about 3-4 cm away from the floor, hit a touch, hitting the ground easy injury and floor heating pipe, thus laying the ground of floor heating pipes are strictly forbidden to break, impact, etc., are strictly prohibited wedging any sharp objects on the ground, in case of damage to floor heating pipe.


5, the user is really necessary drilling on the roof, it is important to pay attention to the drilling depth of no more than the thickness of the floor structure, in case of damage to the upper floor heating pipe.